How to check the side clearance of SCWS200-20-IF worm gear reducer during installation
Publish Time: 2025-10-28 Origin: Site
The main methods to check the side clearance of SCWS200-20-IF worm gear reducer include feeler gauge method, dial indicator method and lead pressure method, as follows:
Feeler gauge method : First clean the meshing tooth surface of the reducer to ensure that no oil, impurities, etc. will affect the measurement. Then use a feeler gauge directly inserted between the meshing teeth of the worm gear and worm to measure the tooth side clearance. When measuring, multiple measurements need to be made at different positions on the worm gear circumference (such as 120° equal positions), and the average value is taken as the backlash value. This method is suitable for situations with large side clearances and is easy to operate, but the accuracy is relatively low.
Dial indicator method : Fix the dial indicator on the box so that the probe of the dial indicator is against the tooth surface of the worm gear. Fix the worm gear, and then rotate the worm forward and backward. The maximum difference between the dial indicator pointer is the backlash. If it is difficult for the dial indicator to directly contact the worm gear tooth surface, a measuring rod can be installed on the worm gear shaft and the backlash can be measured indirectly by measuring the displacement of the measuring rod.
Lead pressing method : Choose a lead wire with a suitable diameter. Generally, the diameter of the lead wire should not exceed 3 times the top gap. Place the lead wire between the meshing teeth of the worm gear and the worm, and turn the worm to squeeze the lead wire. Then take out the extruded lead wire and use a micrometer to measure the thickness of the thinnest part of the lead wire. This thickness value is the tooth side clearance. The lead pressing method has higher measurement accuracy, but the operation is relatively cumbersome.