NAF355-4.5-1 How high temperature can the planetary gear reducer withstand?

Publish Time: 2025-09-12     Origin: Site

NAF355-4.5-1 high temperature bearing capacity of planetary gear reducer

According to the general design standards and material characteristics of industrial reducers, the maximum allowable operating temperature of the NAF355-4.5-1 planetary gear reducer is usually ‌80℃ (shell temperature), but it needs to be comprehensively evaluated in combination with specific working conditions and lubrication conditions.

Key influencing factors

1. Lubrication system

  • When using synthetic lubricating oils (such as ISO VG 320), the upper limit of the oil temperature can reach 90℃ . If it exceeds this temperature, shut down and check.

  • In high temperature environments (>45℃), the rated power needs to be reduced by 10%-15% to avoid temperature rise exceeding the standard.

2. Materials and heat dissipation design‌

  • The high temperature resistance of hard-toothed gears and bearings depends on the material (such as 20CrMnTi carburized steel), which can withstand ‌ 100℃ in the short term , but it is recommended to control the long-term operation below 80℃.

  • If equipped with forced heat dissipation (such as fan or water cooling), it can improve high temperature adaptability to 45℃ ambient temperature + 50℃ temperature rise (ie 95℃)

3. Ambient temperature limit

  • The standard working environment temperature range is ‌ -30℃~+50℃ , and the high-temperature end must ensure the effectiveness of the heat dissipation system.

Abnormal temperature rise determination

  • When shell temperature is >80℃ the or the oil temperature is >90℃ , the machine must be shut down immediately for inspection.

  • Abnormal temperature rise may be accompanied by noise, increased vibration, or deterioration of lubricant (black, metal particles).

Maintenance recommendations

  • Clean the radiator regularly to avoid blockage and cause temperature rise to exceed the standard.

  • It is recommended to check the lubricant oil status every 500 hours in high temperature environments, and replace it with high-temperature resistant synthetic oil (such as L-CKD 320) if necessary.


FEEDBACK

What are the disadvantages of arc gears compared to involute gears in high-speed transmission

What are the differences in the installation methods of output shafts of cycloid pin wheel reducer of different models

What should I pay attention to when adding lubricating oil for different types of cycloid pin wheel reducers?

How to maintain and maintain H3HH7-90 industrial gearbox

Comparison of service life of hard tooth surface and soft tooth surface reducer