How to judge whether the abnormal meshing of the worm gear of the reducer is serious

Publish Time: 2025-11-08     Origin: Site

To determine whether the abnormal meshing of the worm gear of the reducer is serious, a three-dimensional comprehensive assessment of 'operating phenomena + component status + detection data' is required, focusing on whether irreversible damage, safety hazards, or normal operation are affected.


1. Look at the intuitive performance during operation

  1. Slight abnormality: only slight abnormal noise at startup or low speed, which is relieved after no-load operation. The box temperature is ≤80°C and there is no obvious vibration.

  2. Moderate abnormality: Continuous abnormal noise (such as 'gnawing teeth' or 'buzzing'), the noise intensifies under load, the temperature rises between 80-100°C, and the vibration amplitude slightly exceeds the equipment standard.

  3. Serious abnormalities: sharp metal friction or impact sounds, temperature rise exceeding 100°C and continuing to rise, violent vibrations causing the fuselage to shake, and even oil leakage.


2. Check the degree of wear and damage of components

  1. Minor damage: slight pitting corrosion and slight wear on the worm gear tooth surface, no obvious scratches on the worm tooth surface, and the meshing clearance is within the range specified by the manufacturer (usually 0.1-0.3mm).

  2. Moderate damage: The worm gear tooth surface is partially glued, the pitting area is expanded, the worm tooth surface is unevenly worn, the meshing gap exceeds the standard by 1.5 times, and there are no chipped teeth or cracks.

  3. Serious damage: The worm gear tooth surface is glued, peeled off or chipped in a large area, the worm spiral is deformed, the tooth surface is corroded, the meshing gap exceeds the standard by more than 1.5 times, or cracks appear on the components.


3. Measure key operating data

  1. Slight abnormalities: The effective value of vibration speed is ≤2.8mm/s, the oil temperature is stable and has no tendency to rise rapidly, and the output torque fluctuation is ≤5%.

  2. Moderate abnormality: The effective value of vibration speed is between 2.8-7.1mm/s, the oil temperature increases by 5-10°C per hour, and the output torque fluctuates by 5%-10%.

  3. Serious abnormalities: The effective value of the vibration speed is >7.1mm/s, the oil temperature rises sharply (over 10°C per hour), the output torque fluctuates >10%, and even the speed drops suddenly.


4. Determine the impact based on usage scenarios

  1. Minor exception: used for non-critical equipment (such as ordinary conveyor lines), short-term operation does not affect production, and shutdown maintenance can be planned.

  2. Moderate abnormality: critical equipment has a backup unit, or the abnormality is stable and does not worsen, and needs to be shut down within 24-48 hours.

  3. Serious abnormality: Key equipment has no backup, operates under heavy load conditions, or the abnormality continues to worsen, and needs to be shut down immediately to avoid the expansion of the fault.


FEEDBACK

How to judge whether a ZD30-4.5-I soft tooth surface reducer needs to be modified

What are the risks in modifying the ZD40-3.55-I soft tooth surface gear reducer?

What is the normal service life of the WPWDK135-60-A worm gear reducer bearings?

What types of cooling devices are used in the arc gear reducer lubrication and cooling system?

How to correctly install the clamping ring of P2SA29 planetary reducer