How to determine the fault of XWE63-1849-1.5KW horizontal cycloid pinwheel reducer

Publish Time: 2025-05-30     Origin: Site

The method of judging the failure of XWE63-1849-1.5KW horizontal cycloid pin wheel reducer is as follows:


Vibration abnormality :

  • Phenomenon : The shell shakes significantly, and the equipment vibrates significantly.

  • Cause : It may be that the installation foundation is unstable, such as the soft foundation or the installation surface is uneven; the eccentric sleeve bearing is worn, resulting in unstable operation; the cycloid wheel has broken teeth, affecting the transmission accuracy; the coupling centering error exceeds the limit, causing a deviation in power transmission.

  • Inspection method : Use a level to check the installation base to see if its horizontal error is within the range of ≤0.02mm; for bearings and cycloid wheels, wear and breaking conditions can be checked through disassembly; use professional tools to detect the centering of the coupling.

The temperature rise is too high :

  • Phenomenon : During operation of the reducer, the oil temperature exceeds 85℃.

  • Cause : The lubricant Selection is incorrect, not suitable for the current working environment and load; the equipment is overloaded and is in a high load state for a long time; the heat dissipation system is blocked, such as the heat dissipation channel is blocked by dust and other debris, which affects the heat dissipation effect.

  • Inspection method : Check the model and usage of lubricant to confirm whether it meets the requirements; check the workload of the equipment, compare the rated load; clean the heat dissipation channel and observe whether the heat dissipation effect is improved.


Oil leakage :

  • Phenomenon : Oil leakage occurs on the sealing surface of the reducer, bearing end cover and other parts.

  • Cause : The seals such as O-ring on the sealing surface are aging and damaged; the bolts on the bearing end cover are loose, resulting in a tight seal; the ventilation holes are blocked, causing internal pressure to rise and oil leakage.

  • Inspection method : Carefully check the seals at the seal surface and bearing end cover to observe whether there are signs of aging, deformation or damage; check the tightness of the bolts; clean the ventilation holes to ensure they are unobstructed.

Abnormal noise :

  • Phenomenon : The reducer makes abnormal sounds during operation, such as clicking sounds, metal friction sounds, periodic muffled sounds, etc.

  • Cause : The clicking sound may be a wear of the needle pin; the metal friction sound may be an abnormal meshing of the cycloid wheel; the periodic muffled sound may be a bearing damage.

  • Inspection method : Use tools such as stethoscopes to locate the sound source and determine the specific sounding components; check the wear of the needle pin, cycloid wheel and bearing, and measure whether the meshing gap is within a reasonable range of 0.15 - 0.25mm.


FEEDBACK

What are the differences in the requirements for lubricating oil quantity of worm gear reducers of different models

How to determine the working environment temperature of WPA250-50-C worm gear reducer

Introduction to the maintenance method of the CFD250 cooling tower fan reducer

How much impact does the reducer stage have on transmission accuracy and stability?

What are the common damage forms of the output shaft of XLD22-71-2.2KW cycloid pin wheel reducer