How to determine the fault of XWE63-1849-1.5KW horizontal cycloid pinwheel reducer

Publish Time: 2025-05-30     Origin: Site

The method of judging the failure of XWE63-1849-1.5KW horizontal cycloid pin wheel reducer is as follows:


Vibration abnormality :

  • Phenomenon : The shell shakes significantly, and the equipment vibrates significantly.

  • Cause : It may be that the installation foundation is unstable, such as the soft foundation or the installation surface is uneven; the eccentric sleeve bearing is worn, resulting in unstable operation; the cycloid wheel has broken teeth, affecting the transmission accuracy; the coupling centering error exceeds the limit, causing a deviation in power transmission.

  • Inspection method : Use a level to check the installation base to see if its horizontal error is within the range of ≤0.02mm; for bearings and cycloid wheels, wear and breaking conditions can be checked through disassembly; use professional tools to detect the centering of the coupling.

The temperature rise is too high :

  • Phenomenon : During operation of the reducer, the oil temperature exceeds 85℃.

  • Cause : The lubricant Selection is incorrect, not suitable for the current working environment and load; the equipment is overloaded and is in a high load state for a long time; the heat dissipation system is blocked, such as the heat dissipation channel is blocked by dust and other debris, which affects the heat dissipation effect.

  • Inspection method : Check the model and usage of lubricant to confirm whether it meets the requirements; check the workload of the equipment, compare the rated load; clean the heat dissipation channel and observe whether the heat dissipation effect is improved.


Oil leakage :

  • Phenomenon : Oil leakage occurs on the sealing surface of the reducer, bearing end cover and other parts.

  • Cause : The seals such as O-ring on the sealing surface are aging and damaged; the bolts on the bearing end cover are loose, resulting in a tight seal; the ventilation holes are blocked, causing internal pressure to rise and oil leakage.

  • Inspection method : Carefully check the seals at the seal surface and bearing end cover to observe whether there are signs of aging, deformation or damage; check the tightness of the bolts; clean the ventilation holes to ensure they are unobstructed.

Abnormal noise :

  • Phenomenon : The reducer makes abnormal sounds during operation, such as clicking sounds, metal friction sounds, periodic muffled sounds, etc.

  • Cause : The clicking sound may be a wear of the needle pin; the metal friction sound may be an abnormal meshing of the cycloid wheel; the periodic muffled sound may be a bearing damage.

  • Inspection method : Use tools such as stethoscopes to locate the sound source and determine the specific sounding components; check the wear of the needle pin, cycloid wheel and bearing, and measure whether the meshing gap is within a reasonable range of 0.15 - 0.25mm.


FEEDBACK

How to judge the gear wear of the NGW21-8 planetary reducer after the foundation settles

During installation, the ZLYJ250-16 reducer ensures accurate alignment of the output shaft and the screw shaft of the extruder.

Can the KA157RF97-503-4KW reducer continue to operate the equipment when the heating is abnormal?

How to determine whether the heating of the KAT47D90S4/1.1KW/39.6 reducer is normal

How to determine whether the NMRV50-60-0.55KW reducer can work normally at a specific ambient temperature