Article List
-
Things to note when adjusting the gap between the hard tooth surface reducer in ZSC600-37.9-IWhen adjusting the clearance of the ZSC600 - 37.9 - I, the following precautions are given: Check the information in advance: Read the instruction manual or technical manual of the reducer in detail, and clarify the specific methods, parameter requirements and related precautions for adjusting the clearance of this model reducer. Different models of reducers may have differences in structure and adjustment methods, and following the instructions is the basis for ensuring correct adjustment. Ensure safe operation: Be sure to cut off the power supply of the reducer before adjustment and take reliable power-off measures, such as listing warnings, locking power switches, etc., to prevent accidental power-on-operated during the adjustment process and cause safety accidents. Do a good job of cleaning: Before disassembling the reducer shell or performing internal operations, clean the dirt and debris on the surface of the reducer to prevent these impurities from entering the interior during the adjustment process, affecting the gear meshing or aggravating component wear. Check the status of components: comprehensively check the gears, bearings, shafts and other related components.
-
Specific steps to adjust the gap between the hard tooth surface reducer in ZSC(A)500-33.1-4The following are the general specific steps for adjusting the clearance of ZSC (A) 500 - 33.1 - 4: Preparation: Check the instruction manual of the reducer to clarify the relevant requirements and precautions for adjusting the clearance of this model reducer. Cut off the power supply of the reducer and take safety measures, such as a warning for listing to prevent accidental power-on. Prepare the required tools such as a gauge, a dial, a vernier caliper, a wrench, a screwdriver, etc., as well as possible adjustment gaskets and other components. Clean the dirt and debris on the surface of the reducer and keep the working area clean. Measure the original clearance: You can use a feeler gauge to measure the gap between the two teeth, install the gear according to actual use, fix one of the gears so that it cannot rotate, use the feeler gauge to plug the tooth profile gap from the end face (the other gear can be rotated). The maximum reading of the feeler gauge that can be inserted is the tooth side clearance. You can also use a dial meter to measure the head in the middle section of the tooth profile of the movable gear.
-
What are the specific steps for replacing the lubricating oil of RF57-157-2.2KW reducerThe following are the specific steps for replacing the lubricant of RF57-157-2.2KW reducer: Preparation: Make sure the reducer has completely stopped running and the power is cut off, and prepare lubricant, oil connection container, wrench, funnel, filter, cleaning cloth and other tools suitable for the reducer. Oil drain: Place an oil-connecting container under the oil drain screw plug of the reducer, open the ventilator on the top of the reducer case, and then open the oil screw plug to allow lubricating oil to flow into the container. If the reducer has a magnetic plug on the oil drainage block, it needs to be removed and cleaned. Rinse (optional): After the old oil is basically discharged, a small amount of new lubricating oil can be used to rinse the inside of the reducer to remove sediment, metal particles and residual old lubricating oil in the box. The rinsed oil is also discharged through the oil drain port. Cleaning: Wipe the inside of the oil tank and oil pan with a cleaning cloth or filter to ensure that there are no impurities and dirt residues. If conditions permit, you can also use a special cleaning agent to clean it, but be careful to leave the cleaning agent residue after cleaning.
-
RF67-y0.37-95.91 How to reduce the risk while shortening the maintenance cycleHere are some methods to reduce risks while shortening the maintenance cycle of RF67 - y0.37 - 95.91: Develop a reasonable maintenance plan: Develop a detailed and reasonable maintenance plan based on the reducer's user manual and actual operating conditions. Clarify the specific content and key inspection items of each maintenance to avoid excessive maintenance or insufficient maintenance. Training professional maintenance personnel: Ensure that the personnel involved in maintenance have professional knowledge and skills and are familiar with the structure and maintenance requirements of RF67 - y0.37 - 95.91 reducer. Professionally trained personnel can perform maintenance operations more accurately to reduce the risks caused by improper operation. Choose high-quality maintenance materials: use high-quality lubricating oil, seals, fasteners and other maintenance materials that meet the requirements of the reducer. High-quality materials can better meet the operating needs of equipment and reduce the possibility of equipment failure due to material quality problems. Strengthening Day
-
The structural characteristics and precautions of the four series SA77-123.86-1.5KW reducer motorThe four series SA77-123.86-1.5KW reducer motor structural features and precautions: Structural features Gears and worm gears: Use high-quality gears and worm gear materials, and have precision processing and heat treatment. They have high strength, hardness and wear resistance, which can ensure the smoothness and reliability of the transmission and reduce noise. Box: Usually made of high-strength cast iron, with good rigidity and heat dissipation performance, can effectively withstand various forces and torques during the operation of the reducer, and dissipate the heat generated during the operation in a timely manner to ensure that the reducer operates within the normal working temperature range. Bearing: High-performance bearings are selected, which can withstand large radial and axial loads, ensure stable operation of the shaft system, reduce wear and vibration, and extend the service life of the reducer. Sealing device: equipped with a reliable sealing structure, such as oil seals, sealing rings, etc., which effectively prevent lubricating oil leakage, maintain a good lubricating state inside the reducer, and avoid external dust.
-
Is the 7.5KW motor matched with the hard toothed KA107-70.1 gear reducer?The 7.5KW motor and the hard-toothed KA107-70.1 gear reducer are matched. From a power perspective, KA107 The motor that can be matched by the reducer is relatively wide. Some data show that it can match a motor of 3 - 45kW, and some mentions that it can match a motor of 0.18 - 200kW, 7.5kW Within its matching power range. In addition, the reducer model is clearly marked with a 7.5KW motor, indicating that it is designed to be 7.5KW. Motor matching, including the gear strength of the reducer, bearing capacity, etc., are designed to withstand the torque and power output of the 7.5KW motor. However, in practical applications, other factors need to be considered, such as load characteristics, working environment, speed requirements, etc. If the load is an impact load or the working environment is harsh, further verification of Selection may be required and
-
What range should the oil level of the BLD4-11-7.5KW cycloid reducer be maintained?The oil level of the BLD4-11-7.5KW cycloid pin wheel reducer should usually be kept in the centerline of the oil viewing window. A reducer with oil windows horizontally placed, when the machine is stationary, the oil level reaches 2/3 of the oil mirror can also be considered normal. This is because the cycloid reducer generally uses oil pool lubrication. The appropriate oil level can ensure that the transmission components such as gears are fully lubricated, and can also avoid excessive heat generated during operation due to excessive oil level, increased risk of oil leakage, or damage to components due to poor lubrication caused by too low oil level. If the reducer does not have an oil window, refuel when placed horizontally, remove the upper observation cover and insert it vertically into the bottom of the box with a dipstick. The oil level height is generally 55mm−65mm. However, reducers produced by different manufacturers may vary. It is recommended to refer to the equipment's instruction manual to determine the exact oil level range.
-
What are the manifestations of insufficient lubricating oil in BLD5-35-18.5KW cycloid reducerBLD5-35-18.5KW When the lubricant oil of the cycloid reducer is insufficient, the following may occur: abnormal temperature rise: During normal operation, the oil temperature of the reducer is generally maintained at 60℃-80℃. Insufficient lubricant will reduce the heat dissipation area and reduce the heat dissipation efficiency, and the oil temperature may rise to 90℃ or even higher. Long-term high temperature will accelerate the aging and deformation of the seal, resulting in oil leakage, which will make the lubricant oil even less and form a vicious cycle. Increased noise and vibration: lack of protection from lubricating oil, the friction between gears, bearings and other components increases, and the friction sound will be more obvious. At the same time, abnormal vibration may occur, affecting the smooth operation of the reducer. Intensified wear: insufficient lubricating oil cannot form a good oil film on the surface of the component. The contact surfaces of key components such as gears and bearings directly rub against each other, and the friction coefficient increases. For example, the friction coefficient between gears may increase from normal 0.05-0.1 to 0.2 or even higher.
-
How to check whether the soft tooth surface JZQ850-20.49-5 reducer heat sink is installed firmlyTo check whether the soft tooth surface JZQ850-20.49-5 The reducer heat sink is installed firmly, you can refer to the following method: Visual inspection: Check the fixing parts: Carefully observe whether the fixing bolts, nuts or snaps of the heat sink are complete and whether there are any loose, missing or damaged conditions. If the bolt is found to be loose, tighten it in time; if there is any missing or damaged, a new fixing piece needs to be replaced. Check the appearance of the heat sink: Check whether the heat sink has deformation, cracks or damage. If these problems exist, it may affect the fit between the heat sink and the reducer body, and thus affect the heat dissipation effect. The heat sink needs to be corrected or replaced in time. Observe the installation position: Confirm whether the installation position of the heat sink is correct, whether it is closely fitted with the reducer body, and whether there is any misalignment or excessive gap. If so, re-adjustment and installation are required. Manual inspection: Shake the heat sink: When the reducer is shut down and the power is off, gently shake the heat sink to feel whether it has obvious shaking.
-
What faults may occur in the JZQ750-31.5-1 reducer if the heat sink is installed properlyImproper installation of the heat sink may cause the following faults of the JZQ750-31.5-1 The reducer has the following faults: Overheating and poor heat dissipation: The installation position of the heat sink is incorrect. If it is not installed near the heating part of the reducer, or if it is installed too tight or loose, it will affect heat conduction, which will prevent the heat generated inside the reducer from being dispersed into the surrounding environment in time, causing the oil temperature to rise, and thus causing the overall temperature of the reducer to rise. Long-term overheating will accelerate the aging and deterioration of the lubricant, reduce its lubricating performance, and affect the normal operation of the reducer. Local overheating: The heat sink is not installed uniformly, which will lead to uneven heat dissipation on the surface of the reducer and local overheating. This may cause some parts of the reducer to be deformed and damaged due to excessive temperatures, such as deformation of the seal, resulting in oil leakage, and wear of components such as gears and bearings. Increased noise and vibration are not firmly installed to produce additional noise, which may also cause friction between the heat sink and the reducer housing, further increasing