Views: 0 Author: Site Editor Publish Time: 2022-04-06 Origin: Site
1. The concentricity of the cycloid reducer coupling should be tested and checked regularly
2. Check fixed bolts regularly and tighten loose bolts in time to prevent them from falling off during operation. If the reducer often swings in the operation, or the movement is not balanced, it is necessary to check whether the anchor bolt is loose in time, and take reinforcement measures in time.
3. Check the oil level carefully on time and change the oil in time. When changing the oil, keep the inside of the equipment clean and clean the original oil stains. You'd better check to see if there are any scuffed iron chips left. The gear box cleaning machine can use the original oil supply and discharge system of the gear box and the old oil after filtering to clean the gear box, quickly filter the waste oil, add new oil and other functions. In the process of operation, no change of hardware facilities, no addition of detergent, to ensure the safe operation of the gear box, prolong the service life. If not cleaned, easy to affect the working face and bearing life. When injecting special grease, pay attention to ensure sufficient injection amount and quality, so it is best to keep the working environment clean and do not let dust into the lubricating oil.