How to prevent overload of WPS50-50-A worm gear reducer

Publish Time: 2026-01-06     Origin: Site

The key to preventing overload of the WPS50-0-A reducer is to work together in four aspects: Specific measures are as follows:material optimization, lubrication upgrade, load control and regular maintenance .

1. Materials and design optimization

  1. ‌Worm Strengthening‌ : Use 40Cr alloy steel and quench to HRC45-55 to improve the wear resistance of the tooth surface.

  2. ‌Worm gear adaptation‌ : Made of tin bronze (ZCuSn10Pb1), hardness HB80-120, forming a 'hard + soft' pairing with the worm to reduce adhesive wear.

  3. ‌Parameter adjustment‌ : Increase the worm gear displacement coefficient, increase tooth thickness and contact area, and reduce single tooth load.

2. Lubrication system upgrade

  1. ‌Oil product selection‌ :

  • Ordinary working conditions: ISO VG 320/460 mineral oil or special oil for worm gears.

  • Heavy-duty working conditions: synthetic lubricating oil (such as PAO), high temperature resistance (flash point ≥ 240°C).

  • ‌Forced lubrication‌ : When the speed is >1500r/min, the oil pump is used to circulate oil, and the cooler is used to control the oil temperature to ≤70°C.

  • ‌Regular oil change‌ : Change the oil for the first time after the new machine has been running for 500 hours, and then every 2000-3000 hours or every year.

3. Load and operation control

  1. ‌Overload protection‌ :

  • Install a torque limiter (set value is 1.2~1.5 times the rated torque) to prevent slipping and disengagement in case of sudden overload.

  • Install an elastic coupling (such as a serpentine spring coupling) between the motor and the reducer to buffer the startup impact.

  • ‌Soft start optimization‌ : Use a soft starter (starting time ≥10s) to avoid motor starting current shock.

  • ‌Temperature monitoring‌ : When the ambient temperature is >40℃, install a cooling fan or water cooling device to ensure that the shell temperature is ≤90℃.

4. Maintenance and monitoring

  1. ‌Periodic inspection‌ :

  • Stop the machine every 5,000 hours to check the meshing clearance (allowable deviation ±10% of the design value), and adjust the gasket or gear shaft position if it is out of tolerance.

  • Oil samples are taken every 2000 hours for ferrography analysis to monitor the abrasive particle concentration.

  • ‌Non-destructive testing‌ : Conduct magnetic particle testing on gears every 1 to 2 years, focusing on testing the tooth root transition zone.

  • ‌Operating specifications‌ : It is prohibited to start with load and unload before stopping; operators need to be trained to use a stethoscope to judge abnormal noise.

Through the above measures, the risk of overload of the WPS50-50-A reducer can be significantly reduced and the life of the equipment can be extended.


FEEDBACK

How to reduce the load of WPS40-60-B reducer worm gear box

How to prevent overload of WPS50-50-A worm gear reducer

Which gear processing adjustment method is most suitable for ZlY280-6.3-II reducer

What is the applicable scope of the ZLY160-11.2-II reducer gear processing adjustment method?

How to judge whether the FA107-YVPEJ11-4P-58.12-M1 reducer bearing seal is installed correctly