Author: Site Editor Publish Time: 25-03-2026 Origin: Site
To determine whether the WPKS155‑60 worm gear reducer is short of oil, first use the cold shutdown state to check the oil window/oil level plug (the most accurate), and then combine the temperature, noise, leakage, and oil quality to make a comprehensive judgment. Four tricks can quickly diagnose the problem.
1. Static visual inspection (stop the power, cool down to room temperature, must be done)
1. Oil window observation (most commonly used)
Position: Transparent oil mirror on the side of the box (with MIN/MAX or centerline scale).
Standard: The oil level must be between MIN and MAX, preferably above the center line (approximately 2/3); when there is no scale, it is normal for the oil to submerge 1/3 to 1/2 of the worm tooth root and not submerge the worm axis.
Oil shortage judgment: If the oil level is lower than MIN, the oil level cannot be seen, or there is only a small amount of oil stain, it can be directly judged as oil shortage.
2. Check the oil level plug (when there is no oil window)
Location: The oil level plug at the height of the center line on the side of the box (not the oil drain/oil filling hole).
Operation: Place it horizontally, turn off the power and cool down, then unscrew the screw plug; oil slowly overflows → normal; no oil, requires a probe/finger to touch the oil → lack of oil.
3. Leakage investigation
Check whether there is oil leakage at the joint surface of the box, the shaft end oil seal, and the oil drain/oil level plug; long-term oil leakage will lead to oil shortage, and sealing needs to be done simultaneously.
2. Abnormal dynamic operation (typical signal of oil shortage)
1. Temperature soars
The box/bearing seat is hot and the oil temperature is >80°C, or more than 15°C higher than usual; lack of oil causes dry friction and poor heat dissipation, and is the most sensitive to temperature rise.
2. Abnormal noise and vibration
High-frequency whistling, metal friction sound, and vibration become larger; insufficient oil film, dry grinding of the tooth surface/bearing, and increased impact.
3. Rapid deterioration of oil quality
The oil turns black, turbid, has metal shavings, is emulsified, turns white, and smells burnt; lack of oil + high temperature accelerates deterioration, creating a vicious cycle.
3. Exclusive points of WPKS155‑60
Specifications: Center distance 155mm, speed ratio 60, oil bath lubrication, standard oil volume is about 3.5~4L (subject to the manufacturer's manual).
Oil level reference: the center line of the oil window; the oil level screw plug is in the middle of the side. If it is unscrewed and there is no oil, it means there is a lack of oil.
Oil used: L‑CKC 220#/320# medium load industrial gear oil, no mixed grades are allowed.
4. Quick determination process (3 steps to complete)
1. Stop cold state → look at the oil window: lower than MIN → lack of oil; within the range → normal.
2. No oil window → tighten the oil level plug: no oil spill → lack of oil; oil → normal.
3. During operation: temperature rise/howling/oil leakage → oil shortage warning, stop the machine immediately for inspection.
5. Consequences and treatment of oil shortage
Consequences: tooth surface wear, bearing ablation, worm/worm gear gluing, and reducer scrap.
Treatment: replenish the same type of oil to the midline; if the oil quality is poor, drain the oil thoroughly, clean and change the oil; repair leaks.
Explain the application scenario examples of ZDY315-2.63-2 hard tooth surface gear reducer
What impact will the box rupture have on the NGW-L41 reducer?
Can the reduction ratio of NBD1250 planetary reducer be adjusted?
What impact does optimized structural design have on the performance and life of the reducer?
Under which working conditions is it suitable to use hard tooth surface reducer?
What parameters affect the efficiency of WHC150-50-L worm reducer?
How to judge whether the WPKS155-60 worm gear reducer is short of oil
How to clean the vent hole of XLED0.55-53-3481 cycloid reducer
What are the detection methods for output shaft bending of BLEY3322-4189-1.5KW cycloidal reducer?
How to dispose of JZQ500-40.17-4 gear reducer after trial operation
How to choose an oil cooling or water cooling system suitable for R27-15.63-0.25KW reducer
How to judge the fault type of shaft-mounted ZJY150-16-S reducer
How to correctly install the LF60B cooling tower fan reducer
Model meaning and installation features of WPDZ80-30-B worm gear reducer
What are the differences in noise problems between different types of worm gear reducers?
What is the optimal range of the tilt angle of the oil pool of ZSC400-22.4-2 gear reducer?
How to judge the load type of ZFY560-112-2 gear reducer in actual operation
What are the differences between WPWDA worm reducer and WPWD series reducer?
What problems are likely to occur with the seals of the S97 reducer in low temperature environments?