Author: Site Editor Publish Time: 14-09-2022 Origin: Site
1) Thermometer method: This is the simplest method to directly measure temperature, and alcohol thermometer is often used for measurement. During measurement, the thermometer can be placed close to the surface of the bearing to be measured or the stator core to read the temperature indication. When measuring the winding temperature, insert the thermometer into the lifting screw hole of the reducer. The measured temperature value is the winding surface temperature, and the hot spot temperature difference (10. c for Class B insulation) is the hottest spot temperature of the reducer winding. Subtract the ambient temperature from the reducer temperature to obtain the reducer temperature rise.
2) Resistance method: the resistance value of the metal wire increases with the increase of temperature. Within a certain temperature range, there is a certain functional relationship between the resistance value and the temperature. Using this principle, the temperature can be measured by measuring the resistance value of the winding, which is called resistance measurement. When using the resistance method, first measure the cold DC resistance RI of the winding with a bridge, and record that the ambient temperature (room temperature) at that time is small. When the reducer runs for a period of time, then measure the hot DC resistance of the winding, which can be obtained by substituting the formula.
What effect does humidity have on the life of the ZQA350-12.64 reducer?
What are the specific effects of humidity on the operation of ZQ650-31.5-5 gear reducer?
How to judge the degree of gear breakage of ZLYJ146-12.5 reducer
How long does it take to replace the ZLYJ375-16-2 reducer gear after it breaks?
How to adjust the input torque of WHX125-50 worm gear reducer
What is the impact of WHT08-63-8Z reducer box material on noise?
How to check whether the CWU225-2F reducer has a box rupture
What are the causes of poor gear contact in ZLY250-21.73-II reducer?
How will the wear of the CWU250-50-IF worm gear reducer change under different operating conditions?
What are the typical application scenarios of WPEDO70-120-300-0.75KW?
Technical parameters and performance characteristics of WPEDO100-155-150-2.2KW worm gear reducer
How to deal with abnormalities during the trial operation of ZQ250-31.5-4 gear reducer
What tools are needed to replace the bearings of TY125-40-4KW shaft-mounted reducer?
Does the FAF47-36.34-1.5KW gear reducer seal need to be run-in after replacement?
How to ensure accurate alignment when installing WHT80-8-I arc cylindrical worm gear reducer
How to ensure the quality of foundation fixing and leveling of WHX125-40:1 worm gear reducer
What are the specific structural auxiliary measures of CWS200-12.5-SZ worm gear reducer?
Introduce the installation precautions of CWU280-20 worm gear reducer