Author: Site Editor Publish Time: 09-12-2025 Origin: Site
For the WPWO100-30-A worm gear reducer (the worm gear is mostly made of copper alloy and the worm is steel), tooth surface wear prevention needs to focus on the core of 'lubrication protection, load control, installation accuracy, environmental protection, and regular maintenance'. The following are 10 practical measures that can be implemented directly:
1. Select suitable grease/oil: Prioritize the use of special extreme pressure gear oil for worm gears (viscosity grade 220# or 320#). Avoid using oils containing sulfur and phosphorus extreme pressure agents for copper worm gears to prevent chemical corrosion from aggravating wear.
2. Strictly control the lubrication status: replace new oil after 500 hours of first operation, and every 2000-3000 hours thereafter; keep the oil level at the center line of the oil window, and replenish it in time when it is insufficient to avoid dry friction.
3. Limit the operating load range: It is strictly prohibited to exceed the rated load (WPWO100-30-A rated torque is about 450N·m), frequent start and stop or overload impact. When starting, run without load for 3-5 minutes before loading.
4. Ensure installation coaxiality accuracy: the verticality error of the worm and worm gear axis is ≤0.02mm, and the meshing gap is controlled at 0.15-0.3mm to avoid excessive wear of local tooth surfaces caused by unbalanced loads.
5. Clean installation and environment: Before installation, remove iron filings and oil stains from the surface of parts. The operating environment of the equipment must be dust-proof, moisture-proof, and prevent the intrusion of impurities. Regularly clean the reducer shell and surrounding debris.
6. Avoid frequent forward and reverse rotation: Reduce repeated reversing operations in a short period of time, with an interval of ≥3 seconds between each reversal, to reduce tooth surface impact wear and contact fatigue.
7. Control the operating temperature: the normal operating temperature is ≤80°C. If it exceeds 90°C, check the oil quality and heat dissipation, and install a cooling device if necessary.
8. Regularly check the meshing status: stop the machine every 1,000 hours and observe the tooth surface. If there are slight pitting corrosion or scratches, clean them in time and check the oil quality; if the wear is serious, install or load problems need to be checked and accessories replaced.
9. Optimize starting and braking methods: avoid hard starting under load and start smoothly through a frequency converter or soft starter; avoid emergency stops during braking to reduce tooth surface impact loads.
10. Storage and idle protection: When the equipment is idle for a long time, it is necessary to fill it with new oil and turn the worm regularly (once a month, 10 turns each time) to prevent tooth surface corrosion or lubrication failure.
What impact will the vibration of the motor and ZSY200-100-VI reducer have on production quality?
What are the maintenance and upkeep methods of TPS200-20-1F plane enveloping toroidal worm reducer?
How to correctly install TPG100-8 planar enveloping toroidal worm reducer
What are the ways to solve the installation and alignment problems of LF cooling tower fan reducer?
What is the noise level of the CWS100-63-I worm gear reducer?
How to avoid impurities invading the worm gear of WPWDX155-60-4KW reducer
How to prevent worm gear tooth surface wear in WPWO100-30-A reducer
What is the principle of no-load operation method inside the dry DCY gear reducer?
What is the critical load value that causes JZQ200 reducer bearing damage?
What are the common faults in the sealing protection components of P3SA18 planetary reducer?
Introduce the sealing principle of the sealing protection components of P3SA19 planetary reducer
What are the precautions for welding the NGW-S73-2-71 planetary reducer frame?
What are the precautions for the trial operation of the ZQ850-23.34-IVZ reducer after installation?
Comparison of noise levels between hard tooth surface reducers and soft tooth surface reducers
How to judge whether the oil pool depth of QJS-D200-100-II reducer is appropriate
What effect does the depth of the oil pool have on the service life of the QJS-D560-3C-25 reducer?
What are the causes of tooth surface wear of worm gear in WPWK80-40 reducer?
What damage will excessive operating temperature cause to the worm gear of WPDS135-30-B reducer?
How to judge whether the KAF77-17.87-3KW reducer is overloaded by the noise and vibration
What are the steps to replace the output shaft of BWD22-29-4KW cycloid reducer?
Which is better, cycloidal pinwheel reducer or worm gear reducer?
What is the noise change range of the SCWS250-51 worm gear reducer when the load changes?