Author: Site Editor Publish Time: 02-11-2019 Origin: Site
The working temperature of the lubricating oil in the cycloid reducer should generally not exceed 90 degrees Celsius.If the temperature is too high, the physical and chemical properties of the oil will change.For example, reducing the viscosity of the smooth oil will reduce the bearing capacity of the smooth oil film, which may eventually lead to direct contact between the working tooth surface and the side glue.
There are three ways to dissipate the cycloid reducer:
natural cooling
If the ordinary cabinet cannot meet the heat dissipation requirements, heat sinks can be added outside the case, and the heat sinks can be arranged to allow the air to circulate naturally.
2. Fan cooling
If the natural cooling effect of the chassis is not ideal, fan cooling can be used.
3. Water cooling
The oil sump of the cycloid reducer is equipped with a serpentine water pipe.Serpentines are usually made of copper or brass.The pipeline is equipped with cooling water, which takes away the wind heat of the lubricating oil.
What impact does optimized structural design have on the performance and life of the reducer?
Under which working conditions is it suitable to use hard tooth surface reducer?
What parameters affect the efficiency of WHC150-50-L worm reducer?
How to judge whether the WPKS155-60 worm gear reducer is short of oil
How to clean the vent hole of XLED0.55-53-3481 cycloid reducer
What are the detection methods for output shaft bending of BLEY3322-4189-1.5KW cycloidal reducer?
How to dispose of JZQ500-40.17-4 gear reducer after trial operation
How to choose an oil cooling or water cooling system suitable for R27-15.63-0.25KW reducer
How to judge the fault type of shaft-mounted ZJY150-16-S reducer
How to correctly install the LF60B cooling tower fan reducer
Model meaning and installation features of WPDZ80-30-B worm gear reducer
What are the differences in noise problems between different types of worm gear reducers?
What is the optimal range of the tilt angle of the oil pool of ZSC400-22.4-2 gear reducer?
How to judge the load type of ZFY560-112-2 gear reducer in actual operation
What are the differences between WPWDA worm reducer and WPWD series reducer?
What problems are likely to occur with the seals of the S97 reducer in low temperature environments?
WPEDA70-120-200-0.75KW worm gear reducer operation and maintenance specifications
What are the specific applicable scenarios for WPEDA80-135-1.1KW worm gear reducer?
At what temperature does the GSA87-YEJ2.2KW reducer operate best?