Author: Site Editor Publish Time: 31-08-2022 Origin: Site
The international industrial production waterproof level specification IPX and the JIS level of the American manufacturing ground waterproof specification are the same, which are divided into 9 levels of 0-8 and recorded here.
Level 0 unprotected;
Level 1 can also eliminate the harmful effects of small water drops falling vertically;
Level 2: it has safety protection function for water drops falling within 15 degrees from the vertical angle;
Level 3 can also eliminate the harmful effects of spray water droplets with a vertical angle of 60 degrees;
Level 4 can also remove the harmful effects of splashed water drops from other directions;
Level 5 can also eliminate the harmful consequences to the water volume ejected from the nozzles in all directions;
Level 6 can also eliminate the harmful and adverse effects on the super strong water discharge of nozzles in all directions;
The top of level 7 is 0.15-1 m away from the water surface, lasting for 30 minutes. The service performance is not affected and there is no water leakage;
The top of Grade 8 is 1.5-30m away from the water surface, lasting for 30 minutes. The service performance is not adversely affected and there is no water leakage;
In the future, you should pay attention to buying three proofing mobile phones. Only those with level 7 and 8 are really waterproof; Level 6 can also be called rain proof. Mobile phones and GPS for outdoor activities should reach this level.
What effect does humidity have on the life of the ZQA350-12.64 reducer?
What are the specific effects of humidity on the operation of ZQ650-31.5-5 gear reducer?
How to judge the degree of gear breakage of ZLYJ146-12.5 reducer
How long does it take to replace the ZLYJ375-16-2 reducer gear after it breaks?
How to adjust the input torque of WHX125-50 worm gear reducer
What is the impact of WHT08-63-8Z reducer box material on noise?
How to check whether the CWU225-2F reducer has a box rupture
What are the causes of poor gear contact in ZLY250-21.73-II reducer?
How will the wear of the CWU250-50-IF worm gear reducer change under different operating conditions?
What are the typical application scenarios of WPEDO70-120-300-0.75KW?
Technical parameters and performance characteristics of WPEDO100-155-150-2.2KW worm gear reducer
How to deal with abnormalities during the trial operation of ZQ250-31.5-4 gear reducer
What tools are needed to replace the bearings of TY125-40-4KW shaft-mounted reducer?
Does the FAF47-36.34-1.5KW gear reducer seal need to be run-in after replacement?
How to ensure accurate alignment when installing WHT80-8-I arc cylindrical worm gear reducer
How to ensure the quality of foundation fixing and leveling of WHX125-40:1 worm gear reducer
What are the specific structural auxiliary measures of CWS200-12.5-SZ worm gear reducer?
Introduce the installation precautions of CWU280-20 worm gear reducer
What are the application fields of parallel axis helical gear reducer?
What are the common faults in the internal gear transmission system of CJY160-160-LZ-5.5KW reducer?