Author: Site Editor Publish Time: 23-10-2019 Origin: Site
The reducer generates some heat during operation.If it is not irradiated in time, it will cause adverse effects on the body.Therefore, timely heat dissipation is required, and timely heat dissipation can avoid overheating problems of some circuits and protect human body safety.How to improve its cooling efficiency?
1. Increase heat dissipation: If the ordinary cabinet cannot meet the heat dissipation requirements, heat sinks can be added outside the cabinet.Cooling fins should be provided to allow natural circulation of air.It has the advantages of simple structure, convenient installation, good heat dissipation effect and easy serialization.
2. System cooling: use fans to dissipate heat, which is simple and easy to operate.However, the disadvantage of the fan cooling method is that it is not suitable for some situations.For example, when the reducer is scattered in the coal mine, the use of fans will seriously pollute the surrounding working environment and mechanical equipment, and it uses radiation for heat exchange.Heat loss is also limited.
3. Lubricating oil circulation: Install a water cooling or air cooling device outside the reducer to cool the lubricating oil, and the cooled lubricating oil returns to the reducer for lubrication.This type of cooling is primarily intended for use at high power levels or in high ambient temperatures.The advantage lies in the good cooling effect and the long life of the lubricating oil.
Improving the heat dissipation efficiency of the reducer will be more conducive to the heat dissipation of the equipment, and the excess heat will be dissipated in time to prevent the body from overheating.Using it in a ventilated environment has a strong effect on improving efficiency and enhancing heat dissipation.
How to perform maintenance on the ZSC750-34.5-3 reducer with tilted oil pool design during operation
What are the common assembly problems of R57-48.23-0.55KW gear reducer?
What effect does humidity have on the life of the ZQA350-12.64 reducer?
What are the specific effects of humidity on the operation of ZQ650-31.5-5 gear reducer?
How to judge the degree of gear breakage of ZLYJ146-12.5 reducer
How long does it take to replace the ZLYJ375-16-2 reducer gear after it breaks?
How to adjust the input torque of WHX125-50 worm gear reducer
What is the impact of WHT08-63-8Z reducer box material on noise?
How to check whether the CWU225-2F reducer has a box rupture
What are the causes of poor gear contact in ZLY250-21.73-II reducer?
How will the wear of the CWU250-50-IF worm gear reducer change under different operating conditions?
What are the typical application scenarios of WPEDO70-120-300-0.75KW?
Technical parameters and performance characteristics of WPEDO100-155-150-2.2KW worm gear reducer
How to deal with abnormalities during the trial operation of ZQ250-31.5-4 gear reducer
What tools are needed to replace the bearings of TY125-40-4KW shaft-mounted reducer?
Does the FAF47-36.34-1.5KW gear reducer seal need to be run-in after replacement?
How to ensure accurate alignment when installing WHT80-8-I arc cylindrical worm gear reducer
How to ensure the quality of foundation fixing and leveling of WHX125-40:1 worm gear reducer
What are the specific structural auxiliary measures of CWS200-12.5-SZ worm gear reducer?
Introduce the installation precautions of CWU280-20 worm gear reducer