Author: Site Editor Publish Time: 14-09-2022 Origin: Site
1) Thermometer method: This is the easiest way to measure temperature directly, and alcohol thermometers are usually used for measurement.During the measurement, a thermometer can be brought close to the bearing surface or stator core to be measured to read the temperature indication.When measuring the winding temperature, insert the thermometer into the lifting screw hole of the reducer.The measured temperature value is the winding surface temperature, and the hot spot temperature difference (grade 10 insulation) is the hottest spot temperature of the reducer winding.Subtract the ambient temperature from the reduction temperature to obtain the increase in reduction temperature.
2) Resistance method: The resistance value of the metal wire increases with the increase of temperature.Within a certain temperature range, there is a certain functional relationship between resistance value and temperature.Using this principle, the temperature can be measured by measuring the resistance value of the winding, which is called resistance measurement.When using the resistance method, first measure the cold DC resistance RI of the winding with a bridge, and record that the ambient temperature (room temperature) at that time is very small.When the reducer is running for a period of time, then measure the thermal DC resistance of the winding, which can be obtained by substituting the formula.
WPEDA70-120-200-0.75KW worm gear reducer operation and maintenance specifications
What are the specific applicable scenarios for WPEDA80-135-1.1KW worm gear reducer?
At what temperature does the GSA87-YEJ2.2KW reducer operate best?
How to perform maintenance on the ZSC750-34.5-3 reducer with tilted oil pool design during operation
What are the common assembly problems of R57-48.23-0.55KW gear reducer?
What effect does humidity have on the life of the ZQA350-12.64 reducer?
What are the specific effects of humidity on the operation of ZQ650-31.5-5 gear reducer?
How to judge the degree of gear breakage of ZLYJ146-12.5 reducer
How long does it take to replace the ZLYJ375-16-2 reducer gear after it breaks?
How to adjust the input torque of WHX125-50 worm gear reducer
What is the impact of WHT08-63-8Z reducer box material on noise?
How to check whether the CWU225-2F reducer has a box rupture
What are the causes of poor gear contact in ZLY250-21.73-II reducer?
How will the wear of the CWU250-50-IF worm gear reducer change under different operating conditions?
What are the typical application scenarios of WPEDO70-120-300-0.75KW?
Technical parameters and performance characteristics of WPEDO100-155-150-2.2KW worm gear reducer
How to deal with abnormalities during the trial operation of ZQ250-31.5-4 gear reducer
What tools are needed to replace the bearings of TY125-40-4KW shaft-mounted reducer?
Does the FAF47-36.34-1.5KW gear reducer seal need to be run-in after replacement?
How to ensure accurate alignment when installing WHT80-8-I arc cylindrical worm gear reducer
How to ensure the quality of foundation fixing and leveling of WHX125-40:1 worm gear reducer