In daily use, due to improper operation or carelessness, the reducer circuit will be abnormal and burned.What aspects should we pay attention to.
1. The three-phase voltage is unstable.Voltage instability includes different three-phase voltages, three-phase power loss, and low voltage.
2. Repeated operation, repeated operation is the most harmful to the reducer.The current is very large when the reducer is switched on and off.Long-term repeated operation is the biggest cause of burnout of the reducer.
3. Long-term overload and incorrect power selection will cause the machine itself to heat up, and the reducer will burn out after a long time.
4. Water entering the motor is also very harmful.If the motor is energized after being flooded, an internal short circuit will occur and the reducer will be burned.
5. During the operation of the machine, if the transmission is blocked, the reducer will generate a lot of heat, which will burn the machine.
During the operation of the reducer, if there are long-term overloads, water ingress in the motor, etc., if you do not pay attention to the cleaning of the hips, it is easy to cause the reducer to burn out.This will not only cause financial loss, but also affect our work efficiency.Therefore, we must pay attention to the above points during use.
How to deal with abnormalities during the trial operation of ZQ250-31.5-4 gear reducer
What tools are needed to replace the bearings of TY125-40-4KW shaft-mounted reducer?
Does the FAF47-36.34-1.5KW gear reducer seal need to be run-in after replacement?
How to ensure accurate alignment when installing WHT80-8-I arc cylindrical worm gear reducer
How to ensure the quality of foundation fixing and leveling of WHX125-40:1 worm gear reducer
What are the specific structural auxiliary measures of CWS200-12.5-SZ worm gear reducer?
Introduce the installation precautions of CWU280-20 worm gear reducer
What are the application fields of parallel axis helical gear reducer?
What are the common faults in the internal gear transmission system of CJY160-160-LZ-5.5KW reducer?
How to judge whether the thermal expansion gap of FAF87-32r/pm-7.5KW reducer is appropriate
What are the advantages of the pin output structure of BWY12-59-2.2KW cycloidal pinwheel reducer?
How to maintain the BWY15-23-1.5KW reducer with pin output structure
How is the lubrication cycle of K67AM112-15.19-2.2KW gear reducer determined?
What are the technical parameters of RF87-NA45-Y112-D340 reducer?
What are the adaptable working conditions of RF67-11.54-2.2KW reducer in mining machinery?