Author: Site Editor Publish Time: 25-08-2022 Origin: Site
The high-power reducer is a power transmission mechanism that uses the speed converter of the gear to reduce the number of revolutions of the motor to the desired number of revolutions and obtain a larger torque mechanism.After the high-power reducer is put into use, various failures are inevitable. Only by knowing more about the working principle and usage methods of the high-power reducer can the problem be solved when a failure occurs.Today, Dongchen Xiaobian made a detailed analysis on the problem that the high-power reducer does not turn after it is connected to the power supply:
1. Power failure
2. Bearing failure
If it is found that the high-power reducer still cannot run after the above two reasons are detected, it is necessary to detect the problem of the bearing. It may be that the stator and rotor sweeping bores are stuck, causing the gear reducer to fail to rotate.
3. Check the winding to see if there is a fault
The winding may have wiring errors and open circuit, or the winding may be burned, and the machine will stop running.
4. The motor load is too large
If the load of the high-power reducer is too heavy and exceeds the normal working range of the motor, the motor will also stop running.
5. Overcurrent relay
Sometimes this happens when the setting value of the overcurrent relay is too small.The size of this value setting is based on a basis, and the manufacturer should be consulted when setting it.
6. The wiring of the control cabinet is wrong
WPEDA70-120-200-0.75KW worm gear reducer operation and maintenance specifications
What are the specific applicable scenarios for WPEDA80-135-1.1KW worm gear reducer?
At what temperature does the GSA87-YEJ2.2KW reducer operate best?
How to perform maintenance on the ZSC750-34.5-3 reducer with tilted oil pool design during operation
What are the common assembly problems of R57-48.23-0.55KW gear reducer?
What effect does humidity have on the life of the ZQA350-12.64 reducer?
What are the specific effects of humidity on the operation of ZQ650-31.5-5 gear reducer?
How to judge the degree of gear breakage of ZLYJ146-12.5 reducer
How long does it take to replace the ZLYJ375-16-2 reducer gear after it breaks?
How to adjust the input torque of WHX125-50 worm gear reducer
What is the impact of WHT08-63-8Z reducer box material on noise?
How to check whether the CWU225-2F reducer has a box rupture
What are the causes of poor gear contact in ZLY250-21.73-II reducer?
How will the wear of the CWU250-50-IF worm gear reducer change under different operating conditions?
What are the typical application scenarios of WPEDO70-120-300-0.75KW?
Technical parameters and performance characteristics of WPEDO100-155-150-2.2KW worm gear reducer
How to deal with abnormalities during the trial operation of ZQ250-31.5-4 gear reducer
What tools are needed to replace the bearings of TY125-40-4KW shaft-mounted reducer?
Does the FAF47-36.34-1.5KW gear reducer seal need to be run-in after replacement?
How to ensure accurate alignment when installing WHT80-8-I arc cylindrical worm gear reducer
How to ensure the quality of foundation fixing and leveling of WHX125-40:1 worm gear reducer