Author: Site Editor Publish Time: 14-08-2025 Origin: Site
To control the operating conditions of the coaxial TY250-50-45KW gear reducer, it is necessary to start from installation and debugging, lubrication management, load control, monitoring and maintenance, etc., the details are as follows:
Accurate installation and centering : During installation, ensure that the concentricity deviation between the reducer input shaft and the motor shaft, the output shaft and the load shaft is less than 0.05mm. It is recommended to use a laser centering instrument to calibrate it and re-check it after 24 hours of operation to reduce bearing wear and vibration.
Reasonable choice of lubricant : Select the appropriate lubricant viscosity according to the working environment temperature. ISO VG68 lubricating oil is used when the ambient temperature is lower than 0℃, and lubricating oil above VG220 is used in high temperature working conditions. At the same time, the oil level must be controlled well. The liquid level of the oil tank must cover 1-3 times the height of the large gear teeth to avoid excessive or insufficient oil causing heat or insufficient lubrication.
Strictly control the load : calculate the actual torque according to the formula to ensure that there is a safety margin of 15%-20% when Selection to avoid overload operation. For example, when a 45KW motor is equipped with a TY250 reducer, it is necessary to ensure that the actual load torque is within the rated range.
Real-time monitoring of temperature and vibration : Under normal operating conditions, the temperature of the reducer housing should be lower than 85℃. At the same time, the vibration value must comply with the ISO 10816 standard. When the power is greater than 15kW, the vibration speed should be ≤7.1mm/s. Real-time monitoring can be carried out through temperature sensors and vibration sensors. If abnormalities are found, the load status, lubrication system or heat dissipation conditions will be checked in time.
Intelligent control system is adopted : a linkage control system composed of temperature sensors, liquid level sensors, vibration sensors, speed sensors, pressure sensors, noise sensors, data processing centers, controllers and handheld terminals can be installed to collect and monitor multiple operating data such as bearing temperature, vibration, oil level, speed, internal pressure and noise. When any operating data exceeds the set threshold range, the control reducer stops running and notify maintenance personnel to perform maintenance.
Optimized speed regulation method : The frequency conversion speed regulation method can be used to change the power frequency through the inverter, control the motor speed, and then control the operating speed of the reducer. This method has high speed regulation accuracy and high efficiency. Other speed regulation methods such as resistance speed regulation method and mechanical speed regulation method can also be selected according to actual conditions.
Regular maintenance and inspection : Regularly check the sealing structure of the reducer, such as oil seals, ventilation plugs, etc., to prevent dust and water vapor from invading. Especially in harsh environments, it is recommended to conduct sealing performance tests every quarter. At the same time, regularly check the wear of gears and bearings, and replace the worn parts in time.
How to determine the heat dissipation requirements of hard-toothed RS87-7.27 helical gear reducer
How to control the operating conditions of coaxial TY250-50-45KW gear reducer
What are the methods to control the operating conditions of the coaxial TY112-35.5-4KW reducer
What are the common reasons for noise in ZSY450-45-II gear reducer
How to use sound level meter and spectrum analyzer to check noise in ZSY250 gear reducer
Under what circumstances may cause the output shaft of the BLD16-17-18.5KW cycloid reducer to deform
How to prevent the deformation of the output shaft of the BLD13-35-3KW cycloid pin wheel reducer
How to determine the working environment temperature of WPA250-50-C worm gear reducer
Introduction to the maintenance method of the CFD250 cooling tower fan reducer
How much impact does the reducer stage have on transmission accuracy and stability?
What are the common damage forms of the output shaft of XLD22-71-2.2KW cycloid pin wheel reducer
How to repair the output shaft of XLD27-59-3KW cycloid pin wheel reducer if it is worn
Comparison of maintenance costs between hard toothed reducer and soft toothed reducer
How to improve the machining accuracy of RXF97-7.5-358 hard tooth surface gear reducer
List some common noise problems in WPO175-15 worm gear reducer
What are the precautions for WPO200-10-B worm gear reducer during assembly
What are the disadvantages of CWU200-50-3F arc cylindrical worm reducer
How to improve the transmission efficiency of WPA80-15-B worm reducer
What is the impact of lubricating oil replacement cycle on the performance of WPA100-60-A reducer